defmodule Nerves.Runtime do @moduledoc """ Nerves.Runtime contains functions useful for almost all Nerves-based devices. """ alias Nerves.Runtime.{KV, OutputLogger, Power} require Logger # Capture the target that this was built for @mix_target Mix.target() @typedoc """ Options for `Nerves.Runtime.revert/1`. * `:reboot` - Call `Nerves.Runtime.reboot/0` after reverting (defaults to `true`) """ @type revert_options :: {:reboot, boolean()} @doc """ Reboot the device and gracefully shutdown the Erlang VM. This calls `:init.stop/0` internally. If `:init.stop/0` takes longer than the `erlinit.config`'s `--graceful-powerdown` setting (likely 10 seconds) then the system will be hard rebooted. """ @spec reboot() :: no_return() def reboot(), do: Power.run_command("reboot") @doc """ Power off the device. This calls `:init.stop/0` internally. If `:init.stop/0` takes longer than the `erlinit.config`'s `--graceful-powerdown` setting (likely 10 seconds) then the system will be hard rebooted. """ @spec poweroff() :: no_return() def poweroff(), do: Power.run_command("poweroff") @doc """ Halt the device (meaning hang, not power off, nor reboot). Note: this is different than :erlang.halt(), which exits BEAM, and may end up rebooting the device if `erlinit.config` settings allow reboot on exit. """ @spec halt() :: no_return() def halt(), do: Power.run_command("halt") @doc """ Revert the device to running the previous firmware. This requires a specially constructed fw file. """ @spec revert([revert_options]) :: :ok | {:error, reason :: any} | no_return() def revert(opts \\ []) do reboot? = if opts[:reboot] != nil, do: opts[:reboot], else: true revert_fw_path = Application.get_env(:nerves_runtime, :revert_fw_path) if File.exists?(revert_fw_path) do {_, 0} = cmd("fwup", [revert_fw_path, "-t", "revert", "-d", "/dev/rootdisk0"], :info) if reboot? do reboot() else :ok end else {:error, "Unable to locate revert firmware at path: #{revert_fw_path}"} end end @doc """ Return the device's serial number Serial number storage is device-specific and configurable. Serial numbers can be programmed in one-time programmable locations like in CPU ROM or cryptographic elements. They can also be in rewritable locations like a U-Boot environment block. Nerves uses the [`boardid`](https://github.com/nerves-project/boardid/) by default (set `:boardid_path` key in the application environment to another program to override). Boardid uses the `/etc/boardid.config` file to determine how to read the serial number. Official Nerves systems provide reasonable default mechanisms for getting started. Override this file in your application's `rootfs_overlay` to customize it. This function never raises. If a serial number isn't available for any reason, it will return a serial number of `"unconfigured"`. """ @spec serial_number() :: String.t() def serial_number() do boardid_path = Application.get_env(:nerves_runtime, :boardid_path) {serial, 0} = System.cmd(boardid_path, []) String.trim(serial) catch _, _ -> "unconfigured" end @doc """ Mark the running firmware as valid A device cannot receive a new firmware if the current one has not been validated. In the official Nerves systems, this typically happens automatically. If you are handling the firmware validation in your app, then this function can be used as a helper to mark firmware as valid. For systems that support automatic reverting, if the firmware is not marked as valid, then the next reboot will cause a revert to the old firmware """ @spec validate_firmware() :: :ok def validate_firmware() do # If using U-Boot's bootcount feature, set those variables as well if KV.get("upgrade_available") do KV.put(%{"upgrade_available" => "0", "bootcount" => "0", "nerves_fw_validated" => "1"}) else KV.put("nerves_fw_validated", "1") end end @doc """ Return whether the firmware has been marked as valid Since "valid" means that the next boot will run the same firmware, this also returns `true` if firmware validation isn't in use. See `validate_firmware/0` for more information. """ @spec firmware_valid?() :: boolean() def firmware_valid?() do case validation_status() do :validated -> true :unvalidated -> false :unknown -> true end end defp validation_status() do with :unknown <- u_boot_bootcount_status() do nerves_validated_status() end end defp u_boot_bootcount_status() do case KV.get("upgrade_available") do "0" -> :validated "1" -> :unvalidated _ -> :unknown end end defp nerves_validated_status() do case KV.get("nerves_fw_validated") do "1" -> :validated "0" -> :unvalidated _ -> :unknown end end @doc """ Run system command and log output into logger. NOTE: Unlike System.cmd/3, this does not raise if the executable isn't found """ @spec cmd(binary(), [binary()], :debug | :info | :warn | :error | :return) :: {Collectable.t(), exit_status :: non_neg_integer()} def cmd(cmd, params, log_level_or_return) do case System.find_executable(cmd) do nil -> Logger.error( "Executable #{cmd} was not found. The Nerves System must be fixed to include it!" ) {"", 255} cmd_path -> run_cmd(cmd_path, params, log_level_or_return) end end defp run_cmd(cmd, params, :return), do: System.cmd(cmd, params, stderr_to_stdout: true) defp run_cmd(cmd, params, out), do: System.cmd(cmd, params, into: OutputLogger.new(out), stderr_to_stdout: true) @doc """ Return the mix target that was used to build this firmware If you're running on the development machine, this will return `:host`. If not, it will return whatever the user specified with the `MIX_TARGET` environment variable when building this firmware. """ @dialyzer {:nowarn_function, mix_target: 0} @spec mix_target() :: atom() def mix_target(), do: @mix_target end